Short Circuit / Relay Coordination Study Services by Q Sine
Relay Coordination study: Once the relay parameters have been set, a coordination study is performed to ensure that the selected protective relays operate in the desired sequence. The coordination study involves simulating various fault scenarios and verifying that the protective relays operate in the intended sequence.
- Detailed report explaining the input data, system configuration, observations and recommendations
- Fault currents at various buses and branches in the system
- Relay setting charts/tables with optimum settings
- Time coordination curves
- Sequence of Operation
- Relay setting soft file
- Input to Arc Flash Study
Major Covered Parameters
Q Sine specialises in conducting PQA and makes analysis of the data. Based on which the solutions is worked out. We study and capture following data during PQA;
- Peak Voltage and Current
- Active, Reactive and apparent power per phase and their aggregate
- Active, Reactive energy - consumed and produced (export / import)
- Harmonics for voltage, current up to the 50th order
- Power factor. Displacement factor and Tangent
- Crest Factor for V and I & K factor for currents
- Frequency
- Flicker measurements
- Neutral current
- V and I unbalance in %
- Total Harmonic Distortion Factor & Inrush capture
- Transients recording
Common Problems Observed Due to Poor Power Quality
What Our Valued Client Say About Us
Industries We Serve
Case Studies
Sandvik Asia, Pune
Sagar Manufacturers Pvt Ltd, Bhopal
Fresenius Kabi India Pvt. Ltd, Pune
Sampada Paper Mill, Sangli
Yash Industries, Maharashtra
Kisan Agro, Maharashtra
Services Offerings by Q Sine Energy Solutions

Annual Maintenance Contracts Service
We offer our specialised services for the equipment.

Power Quality Audit Service
Q Sine specialises in conducting PQA and makes analysis of the data. Based on which the solution is worked out.

Energy Audit Services
Comprehensive energy audits to identify inefficiencies, reduce energy costs, and improve operational sustainability.

Arc Flash Study Service
Arc Flash Risk Assessment protects employees from electric arc flash hazards in industrial settings.

Load Flow Analysis Services
Analyze electrical network performance to optimize system design, improve efficiency, and ensure reliable power distribution.

Short Circuit and Relay Coordination Study Services
Detailed protection studies to ensure safe electrical systems, proper relay coordination, and minimized fault-related downtime.