Q Sine Enerygy Expert Solutions
We offer holistic solutions for the power disturbances, voltage sag and swell, voltage transients & surges, short & long power outages, Harmonics management, PF Control and Reactive power compensation.
- Because of poor PF there is a heavy penalty in the Electricity bill, which is recurring.
- Major loads like DC Drives, Electric pre heating furnaces, Rolling mills creating fluctuating load pattern, generating of higher Harmonic currents and abnormal voltage variations
- Your own CPP (Captive Power Plant like TG or DG) with Light load condition (Floating Grid) creating poor power quality, resulting into penalty
- Due to the presence of number of Non-Linear loads generation of higher Harmonics are inevitable. This leads to increased failure of Electronic cards / PCBs, this also increases the temperature of connected Transformers, Cables, increases Transformer losses etc.
- Unbalance load due to Process, which risks in Power Connection Termination
What Our Valued Client Say About Us
For our pharma manufacturing unit, Q Sine implemented hybrid solution which gave us desired savings.
Fresenius Kabi India Pvt. Ltd.Project Incharge
With the installation of 2 x 600 A Active Harmonic Filters the harmonics level has been reduced to less than 3% complying to IEEE 519:2014 and now we are having stable PF.
Thank you Q Sine.
Schaeffler India Ltd.Electrical Consultant
We were looking for savings by addressing harmonics related issues and Q SINE installed latest technology of 3 level Active Harmonic Filters at our plant. We are very happy achieving our savings goal in one Sugar season. Also, Our maintenance team have reported lesser failures.
Shahu SugarChief Engineer
Every textile industry faces acute harmonics issues. Q SINE installed 2550A AHF to mitigate our Harmonics issues and compliance to IEEE 519:2014. Now our operations suffer lesser interruption.
Sagar Manufacturers Pvt. Ltd.Project Head
Industries We Serve
Case Studies
Precision Tools
↓60%
THD Reduction
Sandvik Asia, Pune
⚡
Load Details
Industrial machines
⚠️
Before Condition
Current THD was 15%
🔧
Solution Deployed
100 Amp Active Harmonic Filter — 2 units
✅
After Solution
Current THD reduced to 6%
Textiles
2550A
AHF Capacity
Sagar Manufacturers Pvt Ltd, Bhopal
⚡
Load Details
Spinning mill machines
⚠️
Before Condition
Current THD was 15%
🔧
Solution Deployed
150A AHF × 5 units + 300A AHF × 6 units
✅
After Solution
Current THD reduced to 7%
Pharma
0.995
Power Factor
Fresenius Kabi India Pvt. Ltd, Pune
⚡
Load Details
Pharma machines
⚠️
Before Condition
Power Factor was 0.97
🔧
Solution Deployed
510 KVAR Hybrid Panel — RTPFC + SVG
✅
After Solution
Power Factor improved to 0.995
Paper Mill
↓61%
THD Reduction
Sampada Paper Mill, Sangli
⚡
Load Details
Craft paper mill machines
⚠️
Before Condition
THD 18%, VTHD 3.2%
🔧
Solution Deployed
200 Amp Active Harmonic Filter — 1 unit
✅
After Solution
THD 7%, VTHD reduced to 2.5%
CNC Machining
0.995
Power Factor
Yash Industries, Maharashtra
⚡
Load Details
CNC machines
⚠️
Before Condition
Power Factor concern at 0.97
🔧
Solution Deployed
Active Power Factor correction via Static Var Generator (SVG)
✅
After Solution
Power Factor improved to 0.995
Agro Industry
0.995
Power Factor
Kisan Agro, Maharashtra
⚡
Load Details
VFD and motors
⚠️
Before Condition
Harmonics & Power Factor concern
🔧
Solution Deployed
SVG for Power Factor + AHF for Harmonic mitigation
✅
After Solution
PF improved to 0.995 & met IEEE 519:2014 standard
Solution Offerings by Q Sine Energy Solutions
Reactive Power Management Solutions